Impacts of Hemodynamic Parameter on Two Different Sac Size Aneurysm Model at End Systolic and End Diastolic Velocity and Its Variation with Time-Averaged Velocity

Authors

  • Md. Parvez Mahmud Department of Mechanical Engineering, Chittagong University of Engineering and Technology, Chattogram, Raozan-4349, Bangladesh
  • Md Ajwad Mohimin Department of Biomedical Engineering, Texas A&M University, College Station, TX-77840, USA
  • Sultan Hussain Labib Department of Mechanical Engineering, Chittagong University of Engineering and Technology, Chattogram, Raozan-4349, Bangladesh
  • Md. Mamunur Roshid Department of Mechanical Engineering, Chittagong University of Engineering and Technology, Chattogram, Raozan-4349, Bangladesh

DOI:

https://doi.org/10.38032/scse.2026.4.240

Keywords:

Hemodynamics, End Systolic Velocity, End Diastolic Velocity, Cerebral Aneurysm, Non-Newtonian Fluid

Abstract

Hemodynamic parameters like Wall Shear Stress (WSS) and pressure are crucial to predict aneurysm behavior, including growth, stability, and rupture risk. And thus, they can assist the treatment decision. Our objective in this study is to observe variations in such parameters on two different aneurysm models having different sac sizes. This study will investigate End Systolic Velocity (ESV) and End Diastolic Velocity (EDV), and how they affect the hemodynamic parameters. It is expected that these two extreme conditions will provide a good overview of the aneurysm hemodynamics. In this work, the Time-Averaged (TA) inlet flow rate has also been introduced as a baseline reference to compare with the two extremes. ESV gives greater WSS and wall pressure than EDV on both models. This will impose more growth in the sac site in the small sac model. Differences in average WSS were observed between the two aneurysm geometries. The inclusion of TA allows quantification of the relative variations at diastolic and systolic conditions, demonstrating that ESV greatly amplifies WSS compared to TA, whereas EDV remains considerably lower.

Downloads

Downloads

Downloads

Download data is not yet available.

References

[1] N. Chalouhi, B. L. Hoh, and D. Hasan, “Review of cerebral aneurysm formation, growth, and rupture,” Dec. 2013. DOI: https://doi.org/10.1161/STROKEAHA.113.002390

[2] M. B. Pritz, “Cerebral aneurysm classification based on angioarchitecture,” Journal of Stroke and Cerebrovascular Diseases, vol. 20, no. 2, pp. 162–167, Mar. 2011. DOI: https://doi.org/10.1016/j.jstrokecerebrovasdis.2009.11.018

[3] G. J. E. Rinkel, M. Djibuti, A. Algra, and J. Van Gijn, “Prevalence and Risk of Rupture of Intracranial Aneurysms A Systematic Review,” 1998. [Online]. Available: http://ahajournals.org DOI: https://doi.org/10.1161/01.STR.29.1.251

[4] R. Hurford, I. Taveira, W. Kuker, and P. M. Rothwell, “Prevalence, predictors and prognosis of incidental intracranial aneurysms in patients with suspected TIA and minor stroke: A population-based study and systematic review,” BMJ Publishing Group, May 01, 2021. DOI: https://doi.org/10.1136/jnnp-2020-324418

[5] Y. Murayama et al., “Risk Analysis of Unruptured Intracranial Aneurysms: Prospective 10-Year Cohort Study,” Stroke, vol. 47, no. 2, pp. 365–371, Feb. 2016. DOI: https://doi.org/10.1161/STROKEAHA.115.010698

[6] S. A. Mahrous, N. Azwadi, C. Sidik, and K. M. Saqr, “Newtonian and non-Newtonian CFD Models of Intracranial Aneurysm: A Review,” CFD Letters, vol. 12, pp. 62–86, 2020.

[7] J. Bernsdorf and D. Wang, “Non-Newtonian blood flow simulation in cerebral aneurysms,” Computers and Mathematics with Applications, vol. 58, no. 5, pp. 1024–1029, Sep. 2009. DOI: https://doi.org/10.1016/j.camwa.2009.02.019

[8] J. Xiang, A. H. Siddiqui, and H. Meng, “The effect of inlet waveforms on computational hemodynamics of patient-specific intracranial aneurysms,” Journal of Biomechanics, vol. 47, no. 16, pp. 3882–3890, Dec. 2014. DOI: https://doi.org/10.1016/j.jbiomech.2014.09.034

[9] M. L. Raghavan, B. Ma, and R. E. Harbaugh, “Quantified aneurysm shape and rupture risk,” 2005. DOI: https://doi.org/10.3171/jns.2005.102.2.0355

[10] C. W. Ryu, O. K. Kwon, J. S. Koh, and E. J. Kim, “Analysis of aneurysm rupture in relation to the geometric indices: Aspect ratio, volume, and volume-to-neck ratio,” Neuroradiology, vol. 53, no. 11, pp. 883–889, Nov. 2011. DOI: https://doi.org/10.1007/s00234-010-0804-4

[11] M. A. Mohimin, N. M. Arefin, and P. Das, “Cerebral Aneurysm Hemodynamics in Low Hematocrit Conditions: Numerical Simulations and Analysis.” [Online]. Available: https://ssrn.com/abstract=4889257

[12] A. J. Geers, I. Larrabide, H. G. Morales, and A. F. Frangi, “Approximating hemodynamics of cerebral aneurysms with steady flow simulations,” Journal of Biomechanics, vol. 47, no. 1, pp. 178–185, Jan. 2014. DOI: https://doi.org/10.1016/j.jbiomech.2013.09.033

[13] A. J. Weiss et al., “A matched-pair case control study identifying hemodynamic predictors of cerebral aneurysm growth using computational fluid dynamics,” Frontiers in Physiology, vol. 14, 2023. DOI: https://doi.org/10.3389/fphys.2023.1300754

[14] J. H. Chowdhury and K. K. Saha, “Measurement of Peak Systolic Velocities and End Diastolic Velocities of Common Carotid, Internal Carotid and Vertebral Arteries of Healthy Adult Subjects by Duplex Colour Doppler Sonography: A Study of 100 Cases,” 2021. DOI: https://doi.org/10.3329/iahsmj.v4i1.59103

[15] J. R. Cebral, M. A. Castro, C. M. Putman, and N. Alperin, “Flow-area relationship in internal carotid and vertebral arteries,” Physiological Measurement, vol. 29, no. 5, pp. 585–594, May 2008. DOI: https://doi.org/10.1088/0967-3334/29/5/005

[16] P. D. Md. A. I. H. S. Md. Ajwad Mohimin, “EFFECT OF RANS TURBULENCE MODEL ON THE HEMODYNAMIC FACTORS IN A MIDDLE CEREBRAL ARTERY ANEURYSM ,” Chattogram: 7th International Conference on Mechanical Engineering and Renewable Energy 2023.

[17] “Effects of the non-Newtonian viscosity of blood on hemodynamics of diseased artery.”

[18] G. Carty, S. Chatpun, and D. M. Espino, “Modeling Blood Flow Through Intracranial Aneurysms: A Comparison of Newtonian and Non-Newtonian Viscosity,” Journal of Medical and Biological Engineering, vol. 36, no. 3, pp. 396–409, Jun. 2016. DOI: https://doi.org/10.1007/s40846-016-0142-z

Published

02.08.2026

How to Cite

[1]
M. P. . Mahmud, M. A. Mohimin, S. H. Labib, and M. M. Roshid, “Impacts of Hemodynamic Parameter on Two Different Sac Size Aneurysm Model at End Systolic and End Diastolic Velocity and Its Variation with Time-Averaged Velocity”, SCS:Engineering, vol. 4, pp. 555–560, Aug. 2026, doi: 10.38032/scse.2026.4.240.

Similar Articles

1-10 of 83